Recommended Max. PV input power | 66500Wp | ||||||
Max. DC power for single MPPT | 22000W, 16000W | ||||||
Number of MPP trackers | 3 | ||||||
Number of DC inputs | 4/3/3 | ||||||
Max. input voltage | 1000V | ||||||
Start-up voltage | 350V | ||||||
Rated input voltage | 600V | ||||||
MPPT operating voltage range | 250V-950V | ||||||
Full power MPPT voltage range | 530V-800V | ||||||
Max. input MPPT current | 40A/30A/30A | ||||||
Max. input current pet string | 12A | ||||||
Maximum DC input short circuit current per MPPT | 48A/36A/36A |
Rated power | 50000W |
Max. AC power | 50000VA |
Max. Output current | 80A |
Nominal grid voltage | 3/N/PE, 220/380Vac, 230/400Vac, 240/415Vac |
Grid voltage range | 310Vac-480Vac (According to local standard) |
Nominal frequency | 50/60Hz |
Grid frequency range | 45Hz-55Hz/54Hz-66Hz (According to local standard) |
Active power adjustable range | 0~ 100% |
THDi | <3% |
Power factor | >0.99 (adjustable+/-0.8 ) |
Max efficiency | : 98.5% |
European weighted efficiency | : 98.3% |
Self-consumption at night | : <IW |
MPPT efficiency | : >99.9% |
DC reverse polarity protection | : Yes |
DC switch | : Yes |
Protection class/ overvoltage category | : I/II |
Input/ output SPD(III) | : PV: type Il standard, AC: type II optional |
Safety protection | : Anti islanding, RCMU, Ground fault monitoring |
ARPC | : Anti reverse power controller (optional) |
Power management unit | : According to certification and request |
Standard communication mode | : RS485, Wifi/Ethernet/GPRS(optional), SD card, Multi-function relay |
Operation data storage | : 25 years |
Ambient temperature range | : -25°C~ +60°C |
Topology | : Transformerless |
Degree of protection | : IP65 |
Allowable relative humidity range | : 0~ 100% |
Max. operating altitude | : 4000m |
Noise | : <60dB |
Weight | : 68kg |
Cooling | : Fan |
Display | : LCD display |
Warranty | : 5 years/ 7 years/ 10 years |
EMC | : EN 61000-6-2, EN 61000-6-4, EN 61000-3-11, EN 61000-3-12 |
Safety standards | : 1EC62109-1/2, IEC62116, IEC61727, IEC-61683, IEC60068(1,2,14,30) |
Grid standards | : AS/NZS 4777, VDE V 0124-100, V0126-1-1, VDE-AR-N 4105, BDEW,CEI 0-21/CEI 0-16, UNE 206 007-1, EN50549, G99, EN50530, NB/T32004 |