Battery Parameters | |||||||
---|---|---|---|---|---|---|---|
Battery Type | Lithium – Ion, Lead – Acid | ||||||
Nominal bettery voltage | 48V | ||||||
Battery Voltage range | 42-58V | ||||||
Battery Capacity | 50-2000Ah | ||||||
Maximum Charging/Descharging power | 5000W | ||||||
Maximum Charging current | 100A | ||||||
Maximum Descharging current | 100A | ||||||
Charging Curve(Lithium – Ion) | BMS | ||||||
Charging Curve(Lead – Acid) | 3-Stage adaptive with maintenance | ||||||
Depth of Discharge | Lithium – Ion: 0-90% DOD adjustable, Lead – Acid: 0-50% DOD adjustable |
Recommended Max. PV input power | : 9000Wp |
Max DC power for single MPPT | : 4500W |
Max. input voltage | : 600V |
Start-up voltage | : 100V |
Rated input voltage | : 360V |
MPPT operating voltage range | : 90-580V |
Full power MPPT voltage range | : 300V-520V |
Number of MPP trackers | : 2 |
Max. input current per MPPT | : 13A/13A |
Max. input short circuit current per MPPT | : 18A/18A |
Nominal AC Power | : 6000W |
Max. AC power output to utility grid | : 6000VA |
Max. AC power from utility grid | : 12000VA |
Max. AC current output to utility grid | : 27.3A |
Max. AC current from utility grid | : 54.6A |
Nominal grid voltage | : L/N/PE,220V,230V,240V |
Grid voltage range | : 180Vac-276vac(According to local standard ) |
Nominal frequency | : 50Hz/60Hz |
Output THDi | : <3% |
Power factor | : 1 default (+/-0.8 adjustable) |
Max. apparent power | : 5000VA |
Peak output power, duration | : 6000VA,60s |
Max. output current | : 22.7A |
Nominal Voltage ,Frequency | : 220V/230V,50/60Hz |
THDv | : <3% |
Switch Time | : 10ms default |
Max. efficiency of solar inverter | : 98.0% |
European efficiency of solar inverter | : 97.5% |
Max. charging efficiency of battery | : 94.6% |
Max. discharging efficiency of battery | : 94.6% |
PV reverse polarity protection | : Yes |
PV insulation detection | : Yes |
Ground fault monitoring | : Yes |
Over current protection | : Yes |
Over voltage protection | : Yes |
DC Switch | : Yes |
Firm frequency responce function | : Optional |
SPD protection MOV | : Type 3 standard |
Ambient temperature range | : -30℃ ~+60℃(Above 45℃ Derating) |
Standby self-consumption | : <10W |
Topology | : High frequency insolation (for bat) |
Max. parallel operation | : 10 |
Degree of protection | : IP65 |
Allowable relative humidity range | : 0~100% |
Communication | : RS485Wifi/Ethernet/GPRS/4G,CAN2.0 |
Protective class | : Class 1 |
Max. operating altitude | : 4000m |
Current sensor connection | : External |
Noise | : <25dB |
Weight | : 21.5kg |
Cooling | : Natural |
Dimension | : 482*503*183mm |
Display | : LCD&APP+Bluetooth |
Warranty | : 5 years or more |
EMC | : EN 61000-6-2,EN 61000-6-3, EN 61000-3-2, EN 61000-3-3, EN 61000-3-11, EN 61000-3-12 |
Safety standard | : IEC62109-1/2, IEC62040,IEC62116, IEC61727, IEC61683, IEC60068(1,2,14,30) |
Grid standard | : AS/NZS 4777,VDE V 0124-100, V 0126-1-1,VDE-AR-N 4105, CE1 0-21, EN50549,G83/G59/G98/G99, UTE C15-712-I, UNE 206 007-1 |