Max. PV array input power [Wp] | 10000 |
Max. PV input voltage [V] | 600 |
Startup voltage [V] | 50 |
Nominal input voltage [V] | 360 |
MPP tracker voltage range [V] | 40~560 |
No. of MPP trackers/Strings per MPP tracker | 2/1 |
Max. PV input current[A] | 16/16 |
Isc PV Array Short Circuit current [A] | 22/22 |
Rated AC output power [W] | 5000① |
Rated AC output current [A] | 21.7 |
Max. AC output apparent power [VA] | 5000② |
Max. AC output current [A] | 21.7③ |
Nominal AC voltage/AC voltage range [V] | 220/230/240;90~290 |
Nominal AC frequency/AC frequency range [Hz] | 50/60;±5 |
Power Factor range | 0.8 leading~0.8 lagging |
THDi (Rated power) [%] | <3 |
Max. efficiency [%] | : 98 |
Euro. efficiency [%] | : 97 |
Standby consumption [W] @Night | : <3 |
Ingress protection | : IP66 |
Operating ambient temperature range [°C] | : -25~60 |
Max. operation altitude [m] | : 4000 |
Relative humidity [%] | : 0~100 |
Typical noise emission [dB] | : 25⑦ |
Storage temperature [°C] | : -30~70 |
Dimensions (W × H × D) [mm] | : 404×274×146 |
Weight [kg] | : 11 |
Cooling concept | : Natural cooling |
Communication interfaces | : USB/RS485/DRM, Optional: Meter/CT * |
Optional monitoring dongle | : Pocket WiFi/LAN/4G |
Display | : 2 x LED + LCD (16 x 2) / APP |
Over / under voltage protection | : Yes |
DC isolation protection | : Yes |
Monitoring ground fault protection | : Yes |
Grid monitoring | : Yes |
DC injection monitoring | : Yes |
Back feed current monitoring | : Yes |
Residual current detection | : Yes |
Anti-islanding protection | : Yes |
Over temperature protection | : Yes |
SPD (DC/AC) | : Type II / Type II (Optional) |
Arc-fault circuit interrupter (AFCI) | : Optional |
AC auxiliary power supply (APS) | : Optional |
DC Switch | : Optional |
Safety | : IEC / EN 62109-1 / -2 |
EMC | : EN61000-6-1 / 2 / 3 / 4, EN61000-3-2 / 3 / 11 / 12 |
Certification | : IEC61727, EN50549, G98/G99, AS 4777.2, VDE4105, CEI 0-21, VFR, PPDS, TOR |