Half-Cut Mono solar panels have a proven track record of generating stable power over 25 years. These panels have lower resistive losses leading to higher power output. Half-Cut panels can be used in Utility scale projects and/or rooftop application where space is limited.
High Efficiency
Increase production per unit area
Reduce cost of Transportation
Reduce cost of Installation
Reduce utilization area
Reduce cost of BOS
Efficiency upto 21.27%
Best performance on cloudy weather
Linear Performance warranty
10 Year Product Warranty
Model Type | LE144M530H | LE144M535H | LE144M540H | LE144M545H | LE144M550H | |||||
---|---|---|---|---|---|---|---|---|---|---|
STC | NOCT | STC | NOCT | STC | NOCT | STC | NOCT | STC | NOCT | |
Power Output Pmax (W) | 530 | 396.71 | 535 | 400.45 | 540 | 404.19 | 545 | 408.1 | 550 | 411.68 |
Voltage at Pmax V mpp (V) | 40.67 | 38.05 | 40.75 | 38.14 | 40.85 | 38.23 | 40.95 | 38.32 | 41.04 | 38.41 |
Current at Pmax I mpp (I) | 13.04 | 10.43 | 13.14 | 10.5 | 13.23 | 10.57 | 13.32 | 10.65 | 13.41 | 10.72 |
Open-circuit Voltage VOC (V) | 49.32 | 46.52 | 49.41 | 46.59 | 49.5 | 46.67 | 49.59 | 46.75 | 49.68 | 46.83 |
Short-circuit Current ISC (I) | 13.67 | 11.04 | 13.76 | 11.09 | 13.84 | 11.15 | 13.91 | 11.21 | 13.98 | 11.26 |
Module Efficiency % (%) | 20.5 | 20.7 | 20.88 | 21.08 | 21.27 |
More than 93% of the specified output of the module for a 10 years period. More than 84% of the specified output of the module for a 25 years period. 10-year product warranty. 25-year linear performance warranty.
Dimensions (L / W / H) | : 2276mm / 1136mm / 35mm |
Weight | : 28kg |
Front Cover (material / thickness) | : AR coated high transmission low iron tempered glass / 3.2 mm |
Cell (qty. / material / dim./no. of busbars) | : 144 / PERC Monocrystalline Silicon/ 182mm x 182mm / MBB |
Encapsulate (material) | : Ethylene vinyl acetate (EVA) |
Backsheet | : UV Protected |
Frame (material / color ) | : Anodized aluminum alloy / silver |
Junction Box (protection degree) | : IP6 8 Split Junction Box, 3 bypass diodes |
Cable (length / cross-sectional area) | : 400mm / 4mm2 |
Plug Connector (type / protection degree) | : MC4 / IP68 |
Nominal Operating Cell Temperature | : 44+/-2 |
Temperature Coefficient of Pmax | : -0.334 |
Temperature Coefficient of Voc | : -0.286 |
Temperature Coefficient of Isc | : 0.056 |
Max. System Voltage | : 1500VDC |
Max. Series Fuse Rating | : 25A |
Operating Temperature Range | : -40°c to 85°c |
Max. Static Load, Front | : 5400Pa |
Max. Static Load, Back (e.g., wind) | : 2400Pa |
Max. Hailstone Impact (diameter / velocity) | : 25mm / 23.3 m /s |
Number of Modules Per Pallet | : 30 |
Packaging Box Dimensions (L / W / H) | : 2331mm / 1140mm / 1351mm |
Box Weight | : 900kg |