  • DC Input: 200% oversizing, 16A current, ultra wide MPPT voltage range.
  • In-built global MPP scan for higher yields.
  • 10s level interval of data update(Optional, new WiFi dongle required).
  • Multiple interfaces for presenting data.
  • AC/DC built-in Type II SPD (Optional) and I-V curve diagnosis supported.
  • Support external Rapid Shutdown device (RSD).
  • Optional ARC detection (AFCI).
  • Built-in export control function.
  • Adapt to Home EV Charger Solution.
  • Mass management and broad extension via Datahub.
  • Extendable parallel solution via Modbus supporte.

Max. PV array input power [Wp] 6600
Max. PV input voltage [V] 550
Startup voltage [V] 50
Nominal input voltage [V] 360
MPP tracker voltage range [V] 40~450
No. of MPP trackers/Strings per MPP tracker 1/1
Max. PV input current[A] 16
Isc PV Array Short Circuit current [A] 22
Rated AC output power [W] 3300
Rated AC output current [A] 14.4
Max. AC output apparent power [VA] 3300
Max. AC output current [A] 15
Nominal AC voltage/AC voltage range [V] 220/230/240;90~290
Nominal AC frequency/AC frequency range [Hz] 50/60;±5
Power Factor range 0.8 leading~0.8 lagging
THDi (Rated power) [%] <3

Technical Data

  • System Data

    Max. efficiency [%] : 98
    Euro. efficiency [%] : 97
    Standby consumption [W] @Night : <1
    Ingress protection : IP66
    Protection class : Class I
    Over voltage category : II (DC),III (AC)
    Operating ambient temperature range [°C] : -25~60
    Max. operation altitude [m] : <4000
    Humidity [%] : 0~100
    Typical noise emission [dB] : 25
    Storage temperature [°C] : -30~70
    Dimensions (W×H×D) [mm] : 290x206x120
    Weight [kg] : 5.5
    Cooling concept : Natural cooling
    Communication interfaces : USB/RS485/DRM, Optional: Meter/CT *
    Optional monitoring dongle : Pocket WiFi/LAN/4G
    Display : 2 x LED + LCD(16 x 2) / APP
  • Protection

    Over/under voltage protection : Yes
    DC isolation protection : Yes
    Monitoring ground fault protection : Yes
    Grid monitoring : Yes
    DC injection monitoring : Yes
    Back feed current monitoring : Yes
    Residual current detection : Yes
    Anti-islanding protection : Yes
    Over temperature protection : Yes
    SPD (DC/AC) : Type II / Type II (Optional)
    Arc-fault circuit interrupter (AFCI) : Optional
    AC auxiliary power supply (APS) : Optional
    DC Switch : Optional
  • Standard

    Safety : EN/IEC62109-1/2
    EMC : EN61000-6-1/2/3/4; EN61000-3-2/3/11/12
    Certification : IEC61727, EN50549, G98/G99, AS 4777.2, VDE4105, CEI 0-21, VFR