Max. PV array input power [KWp] | 165 |
Max. PV input voltage [V] | 1100 |
Startup voltage [V] | 200 |
Nominal input voltage [V] | 580/600 |
MPP tracker voltage range [V] | 180~1000 |
No. of MPP trackers | 9 |
Strings per MPP tracker | 2 |
Max. input current per MPPT [A] | 32 |
Max. short circuit current per MPPT [A] | 46 |
Nominal AC output power [KW] | 110 |
Nominal AC output current [A] | 166.7/159.5 |
Max. AC output apparent power [KVA] | 121 |
Max. AC output current [A] | 183.4/175.4 |
Nominal AC voltage [V] | 220/380, 230/400, 3/N/PE, 3/PE |
Nominal grid frequency[Hz] | 50/60 |
Displacement power factor | 0.8 leading-0.8 lagging |
THDi (Rated power) [%] | <3 |
MPPT efficiency [%] | : 99.9 |
Max. efficiency [%] | : 98.6 |
Ingress protection | : IP66 |
Operating temperature range [°C] | : -30~+60 |
Max. operation altitude [m] | : 4000 |
Relative humidity [%] | : 0~100 |
Dimensions[W×H×D] [mm] | : 985×660×327.5 |
Weight [kg] | : 83 |
Cooling concept | : Smart fan cooling |
Communication interfaces | : RS485 / (Optional: Pocket WiFi/LAN/4G) / PLC(Optional) / USB |
Display | : LCD(Optional)/LED*4 |
Over/under voltage protection | : YES |
DC isolation protection | : YES |
Grid monitoring | : YES |
DC injection monitoring | : YES |
Residual current detection | : YES |
Anti-islanding protection | : YES |
String fault detection | : YES |
SPD (DC/AC) | : Type II / Type II |
Arc-fault circuit interrupter(AFCI) | : Optional |
AC terminals over temperature detection | : YES |
AC auxiliary power supply(APS) | : Optional |
Power line communication(PLC) | : Optional |
Safety | : IEC/EN 62109-1; IEC/EN 62109-2; NB/T 32004 |
EMC | : IEC/EN 61000; NB/T 32004 |
Certification | : EN 50549; AS4777.2; VDE4105; IEC 61727; IEC 62116; IEC 61683; IEC 60068; EN 50530; NB/T 32004 |